50H UW Wustermark
• 50Hertz
28,216Total MWh
220Measures
31 MWAvg Power
220Curtailments
0Ramp-ups
Data: 2024-01-13 to 2026-09-30
Daily Redispatch Volume
| Date | Measures | Total MWh |
|---|---|---|
| 2026-09-30 | 2 | 60 |
| 2026-09-29 | 2 | 210 |
| 2026-09-28 | 2 | 28 |
| 2026-09-24 | 1 | 49 |
| 2026-09-22 | 1 | 17 |
| 2026-09-21 | 2 | 178 |
| 2026-09-20 | 1 | 474 |
| 2026-09-16 | 1 | 5 |
| 2026-09-06 | 1 | 14 |
| 2026-09-05 | 1 | 371 |
| 2026-08-31 | 1 | 84 |
| 2026-08-29 | 1 | 42 |
| 2026-08-27 | 1 | 225 |
| 2026-08-25 | 1 | 4 |
| 2026-08-15 | 1 | 43 |
| 2026-08-14 | 1 | 20 |
| 2026-08-11 | 1 | 24 |
| 2026-08-10 | 1 | 8 |
| 2026-08-03 | 1 | 10 |
| 2026-07-25 | 1 | 0 |
| 2026-07-08 | 1 | 295 |
| 2026-06-22 | 1 | 1 |
| 2026-06-21 | 1 | 14 |
| 2026-06-12 | 1 | 3 |
| 2026-06-11 | 2 | 27 |
| 2026-06-09 | 1 | 90 |
| 2026-06-02 | 1 | 5 |
| 2026-05-28 | 1 | 1 |
| 2026-05-19 | 1 | 0 |
| 2026-05-18 | 2 | 14 |
Recent Measures
| Date | TSO | Dir | Avg MW | MWh | Time |
|---|---|---|---|---|---|
| 2026-09-30 | 50Hertz | negative | 40 | 30 | 09:September-11:September |
| 2026-09-30 | 50Hertz | negative | 40 | 30 | 09:September-11:September |
| 2026-09-29 | 50Hertz | negative | 21 | 105 | 09:September-15:September |
| 2026-09-29 | 50Hertz | negative | 21 | 105 | 09:September-15:September |
| 2026-09-28 | 50Hertz | negative | 4 | 14 | 08:September-14:September |
| 2026-09-28 | 50Hertz | negative | 4 | 14 | 08:September-14:September |
| 2026-09-24 | 50Hertz | negative | 33 | 49 | 11:September-14:September |
| 2026-09-22 | 50Hertz | negative | 8 | 17 | 10:September-13:September |
| 2026-09-21 | 50Hertz | negative | 48 | 24 | 12:September-15:September |
| 2026-09-21 | 50Hertz | negative | 47 | 154 | 06:September-10:September |
| 2026-09-20 | 50Hertz | negative | 79 | 474 | 16:September-22:September |
| 2026-09-16 | 50Hertz | negative | 19 | 5 | 10:September-11:September |
| 2026-09-06 | 50Hertz | negative | 28 | 14 | 06:September-07:September |
| 2026-09-05 | 50Hertz | negative | 62 | 371 | 16:September-22:September |
| 2026-08-31 | 50Hertz | negative | 42 | 84 | 14:August-16:August |
| 2026-08-29 | 50Hertz | negative | 42 | 42 | 13:August-14:August |
| 2026-08-27 | 50Hertz | negative | 38 | 225 | 08:August-14:August |
| 2026-08-25 | 50Hertz | negative | 18 | 4 | 09:August-09:August |
| 2026-08-15 | 50Hertz | negative | 25 | 43 | 13:August-14:August |
| 2026-08-14 | 50Hertz | negative | 5 | 20 | 09:August-14:August |
| 2026-08-11 | 50Hertz | negative | 12 | 24 | 13:August-15:August |
| 2026-08-10 | 50Hertz | negative | 33 | 8 | 14:August-15:August |
| 2026-08-03 | 50Hertz | negative | 5 | 10 | 09:August-11:August |
| 2026-07-25 | 50Hertz | negative | 1 | 0 | 15:July-15:July |
| 2026-07-08 | 50Hertz | negative | 37 | 295 | 08:July-16:July |
| 2026-06-22 | 50Hertz | negative | 1 | 1 | 09:June-10:June |
| 2026-06-21 | 50Hertz | negative | 14 | 14 | 10:June-11:June |
| 2026-06-12 | 50Hertz | negative | 13 | 3 | 11:June-11:June |
| 2026-06-11 | 50Hertz | negative | 8 | 6 | 10:June-10:June |
| 2026-06-11 | 50Hertz | negative | 7 | 21 | 07:June-13:June |
| 2026-06-09 | 50Hertz | negative | 36 | 90 | 11:June-14:June |
| 2026-06-02 | 50Hertz | negative | 3 | 5 | 09:June-11:June |
| 2026-05-28 | 50Hertz | negative | 1 | 1 | 08:May-09:May |
| 2026-05-19 | 50Hertz | negative | 1 | 0 | 08:May-08:May |
| 2026-05-18 | 50Hertz | negative | 3 | 4 | 11:May-13:May |
| 2026-05-18 | 50Hertz | negative | 5 | 10 | 07:May-09:May |
| 2026-05-16 | 50Hertz | negative | 23 | 164 | 08:May-15:May |
| 2026-05-14 | 50Hertz | negative | 40 | 120 | 08:May-11:May |
| 2026-05-12 | 50Hertz | negative | 13 | 45 | 10:May-14:May |
| 2026-04-28 | 50Hertz | negative | 7 | 10 | 11:April-12:April |
| 2026-04-26 | 50Hertz | negative | 2 | 2 | 08:April-08:April |
| 2026-04-26 | 50Hertz | negative | 5 | 10 | 06:April-08:April |
| 2026-04-26 | 50Hertz | negative | 22 | 44 | 03:April-06:April |
| 2026-04-25 | 50Hertz | negative | 33 | 16 | 08:April-09:April |
| 2026-04-25 | 50Hertz | negative | 33 | 16 | 08:April-09:April |
| 2026-04-23 | 50Hertz | negative | 20 | 70 | 06:April-10:April |
| 2026-04-23 | 50Hertz | negative | 20 | 70 | 06:April-10:April |
| 2026-04-22 | 50Hertz | negative | 16 | 80 | 08:April-13:April |
| 2026-04-22 | 50Hertz | negative | 16 | 80 | 08:April-13:April |
| 2026-04-21 | 50Hertz | negative | 7 | 2 | 14:April-14:April |
Frequently Asked Questions
What is the redispatch history of 50H UW Wustermark?
50H UW Wustermark is a Erneuerbar power plant in the 50Hertz grid zone. It has received 220 redispatch instructions totaling 28,216 MWh since 2024-01-13.
Why is 50H UW Wustermark frequently redispatched?
Plants in the 50Hertz zone are frequently curtailed due to grid congestion from excess renewable generation in Northern Germany. This is part of Germany's structural North-South grid bottleneck.