Jänschwalde (Standort)

Konventionell50Hertz

528,618Total MWh
919Measures
124 MWAvg Power
808Curtailments
111Ramp-ups

Data: 2024-01-04 to 2026-08-14

Daily Redispatch Volume

DateMeasuresTotal MWh
2026-08-14 1 513
2026-08-13 3 568
2026-08-12 1 162
2026-08-11 1 66
2026-08-10 2 504
2026-08-03 1 579
2026-07-31 2 272
2026-07-29 1 7
2026-07-27 1 68
2026-07-26 3 1,273
2026-07-24 2 1,019
2026-07-23 1 27
2026-07-22 3 5,629
2026-07-21 2 422
2026-07-19 3 678
2026-07-17 1 300
2026-07-16 1 537
2026-07-10 2 324
2026-07-09 2 604
2026-07-08 1 207
2026-07-07 2 2,021
2026-07-06 2 2,496
2026-07-04 4 1,104
2026-07-03 1 855
2026-07-02 2 2,859
2026-07-01 1 105
2026-06-26 1 332
2026-06-25 1 158
2026-06-24 4 1,400
2026-06-23 1 746

Recent Measures

DateTSODirAvg MWMWhTime
2026-08-14 50Hertz negative 171 513 06:August-09:August
2026-08-13 50Hertz negative 38 38 15:August-16:August
2026-08-13 50Hertz negative 240 240 07:August-08:August
2026-08-13 50Hertz negative 145 290 06:August-08:August
2026-08-12 50Hertz negative 72 162 06:August-09:August
2026-08-11 50Hertz negative 33 66 15:August-17:August
2026-08-10 50Hertz negative 112 224 18:August-20:August
2026-08-10 50Hertz negative 70 280 17:August-21:August
2026-08-03 50Hertz negative 193 579 23:August-02:August
2026-07-31 50Hertz negative 9 7 09:July-12:July
2026-07-31 50Hertz negative 212 265 07:July-09:July
2026-07-29 50Hertz negative 29 7 08:July-08:July
2026-07-27 50Hertz negative 68 68 22:July-23:July
2026-07-26 50Hertz negative 24 66 22:July-07:July
2026-07-26 50Hertz negative 226 1,132 22:July-07:July
2026-07-26 50Hertz negative 100 75 16:July-16:July
2026-07-24 50Hertz negative 87 109 06:July-08:July
2026-07-24 50Hertz negative 140 910 02:July-09:July
2026-07-23 50Hertz negative 107 27 04:July-04:July
2026-07-22 50Hertz negative 241 1,444 22:July-04:July
2026-07-22 50Hertz negative 288 1,725 16:July-22:July
2026-07-22 50Hertz negative 273 2,460 05:July-22:July
2026-07-21 50Hertz negative 202 354 06:July-08:July
2026-07-21 50Hertz negative 135 68 06:July-07:July
2026-07-19 50Hertz positive 112 224 08:July-10:July
2026-07-19 50Hertz negative 95 190 04:July-06:July
2026-07-19 50Hertz negative 132 264 02:July-06:July
2026-07-17 50Hertz negative 300 300 08:July-09:July
2026-07-16 50Hertz negative 239 537 07:July-09:July
2026-07-10 50Hertz negative 67 84 07:July-09:July
2026-07-10 50Hertz negative 120 240 07:July-09:July
2026-07-09 50Hertz negative 98 196 08:July-10:July
2026-07-09 50Hertz negative 117 408 07:July-11:July
2026-07-08 50Hertz negative 32 207 07:July-19:July
2026-07-07 50Hertz negative 145 1,599 22:July-17:July
2026-07-07 50Hertz negative 70 422 05:July-22:July
2026-07-06 50Hertz negative 146 1,350 22:July-22:July
2026-07-06 50Hertz negative 191 1,146 16:July-22:July
2026-07-04 50Hertz negative 121 663 22:July-20:July
2026-07-04 50Hertz negative 94 164 20:July-22:July
2026-07-04 50Hertz negative 59 176 17:July-20:July
2026-07-04 50Hertz negative 81 101 04:July-05:July
2026-07-03 50Hertz negative 171 855 17:July-22:July
2026-07-02 50Hertz negative 163 1,463 22:July-19:July
2026-07-02 50Hertz negative 279 1,396 17:July-22:July
2026-07-01 50Hertz negative 35 105 23:July-02:July
2026-06-26 50Hertz negative 111 332 06:June-09:June
2026-06-25 50Hertz negative 53 158 07:June-17:June
2026-06-24 50Hertz negative 55 55 08:June-09:June
2026-06-24 50Hertz negative 89 22 07:June-08:June

Frequently Asked Questions

What is the redispatch history of Jänschwalde (Standort)?

Jänschwalde (Standort) is a Konventionell power plant in the 50Hertz grid zone. It has received 919 redispatch instructions totaling 528,618 MWh since 2024-01-04.

Why is Jänschwalde (Standort) frequently redispatched?

Plants in the 50Hertz zone are frequently curtailed due to grid congestion from excess renewable generation in Northern Germany. This is part of Germany's structural North-South grid bottleneck.