← 2026-09-18

Saturday, September 19, 2026

2026-09-20 →
554MWh Curtailed
1,015MWh Ramped Up
€0.38MEst. Cost
149 MWPeak Positive

Day-Ahead Spot: -2-134 €/MWh (avg 36)

TSO Breakdown

TSODirectionMeasuresTotal MWh
TenneT DE negative 28 97,498
Amprion positive 28 71,181
TransnetBW positive 23 33,184
TenneT DE positive 9 22,181
50Hertz negative 14 3,336
50Hertz positive 3 2,358
Amprion negative 3 665
TransnetBW negative 1 94

Plant-Level Redispatch Measures

PlantTSOFuelDirAvg MWMWhTime
UW Dörpen-West TenneT DE Erneuerbar negative 1322 23,792 04:September-22:September
UW Büttel TenneT DE Erneuerbar negative 1019 18,343 04:September-22:September
Börse TenneT DE Sonstiges positive 1035 14,754 22:September-22:September
UW Diele TenneT DE Erneuerbar negative 672 12,100 04:September-22:September
WEISWEILER_G Amprion Konventionell positive 458 11,003 22:September-22:September
UW Dörpen-West TenneT DE Erneuerbar negative 1814 10,881 22:September-04:September
Grosskraftwerk Mannheim Block 9 TransnetBW Konventionell positive 351 8,422 22:September-22:September
UW Emden-Ost TenneT DE Erneuerbar negative 600 8,251 04:September-22:September
NIEDERAUSSEM_H Amprion Konventionell positive 342 8,217 22:September-22:September
NIEDERAUSSEM_K Amprion Konventionell positive 412 7,103 22:September-22:September
NEURATH_F Amprion Konventionell positive 405 5,876 22:September-22:September
UW Diele TenneT DE Erneuerbar negative 903 5,420 22:September-04:September
Reservekraftwerk Heilbronn Block 7 TransnetBW Konventionell positive 548 4,380 14:September-22:September
WEISWEILER_G Amprion Konventionell positive 340 4,252 06:September-20:September
NIEHL-31-GUD Amprion Konventionell positive 238 3,980 01:September-22:September
UW Büttel TenneT DE Erneuerbar negative 486 3,161 22:September-16:September
Reservekraftwerk Rheinhafen-Dampfkraftwerk Karlsruhe Block 4 TransnetBW Konventionell positive 272 2,990 23:September-22:September
Irsching 5 TenneT DE Konventionell positive 425 2,868 14:September-21:September
Emsland Block D Amprion Konventionell positive 270 2,767 00:September-21:September
UW Garrel-Ost alpha TenneT DE Erneuerbar negative 248 2,725 04:September-22:September
Grosskraftwerk Mannheim Block 9 TransnetBW Konventionell positive 221 2,704 05:September-22:September
NIEHL-II Amprion Konventionell positive 169 2,698 22:September-22:September
Reservekraftwerk Rheinhafen-Dampfkraftwerk Karlsruhe Block 4 TransnetBW Konventionell positive 251 2,507 12:September-22:September
NIEHL-31-GUD Amprion Konventionell positive 312 2,493 22:September-22:September
NIEDERAUSSEM_K Amprion Konventionell positive 267 2,470 05:September-22:September
NIEHL-II Amprion Konventionell positive 245 2,447 12:September-22:September
Irsching 4 TenneT DE Konventionell positive 305 2,444 14:September-22:September
illwerke vkw AG TransnetBW Sonstiges positive 328 2,299 04:September-21:September
Netzreservekraftwerk Bexbach A Amprion Konventionell positive 346 2,078 15:September-22:September
WEISWEILER_G Amprion Konventionell positive 197 2,016 01:September-22:September
Heizkraftwerk Altbach/Deizisau Block 2 TransnetBW Konventionell positive 251 2,008 14:September-22:September
Boxberg (Standort) 50Hertz Konventionell positive 280 1,958 00:September-07:September
Netzreservekraftwerk HERNE_4 Amprion Konventionell positive 95 1,837 01:September-22:September
NIEHL-31-GUD Amprion Konventionell positive 182 1,724 05:September-16:September
Emsland Block D Amprion Konventionell positive 330 1,648 22:September-03:September
AVA Cluster Voslapp TenneT DE Erneuerbar negative 273 1,636 16:September-22:September
Reservekraftwerk Altbach/Deizisau Block 1 TransnetBW Konventionell positive 260 1,560 22:September-04:September
UW Emden-Ost TenneT DE Erneuerbar negative 211 1,528 08:September-16:September
NEURATH_G Amprion Konventionell positive 301 1,503 03:September-08:September
Netzreservekraftwerk Bexbach A Amprion Konventionell positive 246 1,478 16:September-22:September
UW Emden-Ost TenneT DE Erneuerbar negative 260 1,363 22:September-14:September
Reservekraftwerk Heilbronn Block 7 TransnetBW Konventionell positive 335 1,340 22:September-02:September
Reservekraftwerk Altbach/Deizisau Block 1 TransnetBW Konventionell positive 217 1,300 16:September-22:September
NEURATH_F Amprion Konventionell positive 206 1,239 04:September-17:September
ReserveKW Zolling 5 TenneT DE Konventionell positive 248 1,238 01:September-06:September
AVA Cluster Voslapp TenneT DE Erneuerbar negative 119 1,162 06:September-16:September
NIEDERAUSSEM_H Amprion Konventionell positive 96 1,155 03:September-22:September
Netzreservekraftwerk HERNE_4 Amprion Konventionell positive 177 1,060 22:September-22:September
WEISWEILER_H Amprion Konventionell positive 263 1,053 03:September-07:September
SHN Cluster Heide West T411 T412 TenneT DE Erneuerbar negative 137 1,025 14:September-22:September

How BESS Can Reduce These Costs

Battery Energy Storage Systems at congestion points could have avoided an estimated €0.11M of today's redispatch costs by absorbing excess wind energy locally.

Learn BESS Arbitrage (Free) Stromfee AI Platform

Frequently Asked Questions

How much did redispatch cost on 2026-09-19?

On 2026-09-19, estimated redispatch costs were approximately €0.38 million. This includes €0.06M for renewable curtailment compensation and €0.07M for conventional ramp-up costs.

Which power plants were most affected on 2026-09-19?

The most affected plant was UW Dörpen-West (TenneT DE) with 23,792 MWh of negative redispatch.

What was the electricity spot price on 2026-09-19?

The EPEX Day-Ahead spot price for DE_LU ranged from -2 to 134 €/MWh with an average of 36 €/MWh.