3,023MWh Curtailed
2,673MWh Ramped Up
€0.9MEst. Cost
176 MWPeak Positive
Day-Ahead Spot: 0-177 €/MWh (avg 113)
TSO Breakdown
| TSO | Direction | Measures | Total MWh |
|---|---|---|---|
| TenneT DE | positive | 5 | 20,202 |
| TenneT DE | negative | 9 | 17,512 |
| Amprion | positive | 9 | 11,077 |
| 50Hertz | negative | 17 | 2,292 |
| TransnetBW | positive | 2 | 606 |
| TransnetBW | negative | 2 | 393 |
| 50Hertz | positive | 4 | 234 |
| Amprion | negative | 2 | 85 |
Plant-Level Redispatch Measures
| Plant | TSO | Fuel | Dir | Avg MW | MWh | Time |
|---|---|---|---|---|---|---|
| Börse | TenneT DE | Sonstiges | positive | 901 | 14,873 | 23:July-22:July |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 417 | 9,284 | 23:July-22:July |
| Irsching 4 | TenneT DE | Konventionell | positive | 328 | 2,545 | 22:July-22:July |
| HAMMUENTROP_20 | Amprion | Konventionell | positive | 261 | 2,414 | 23:July-08:July |
| BAG NWAK-Cluster 15 Pleinting | TenneT DE | negative | 250 | 2,250 | 08:July-17:July | |
| HERDECKE_H6 | Amprion | Konventionell | positive | 223 | 2,010 | 23:July-08:July |
| HUCKINGEN_A | Amprion | Konventionell | positive | 80 | 1,900 | 22:July-22:July |
| BAG NWAK-Cluster 17 Altheim | TenneT DE | negative | 200 | 1,800 | 08:July-17:July | |
| GERSTEINW_F (KapRes) | Amprion | Konventionell | positive | 144 | 1,580 | 22:July-09:July |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 270 | 1,418 | 22:July-03:July |
| Börse | TenneT DE | Sonstiges | negative | 248 | 1,362 | 14:July-20:July |
| Börse | TenneT DE | Sonstiges | positive | 363 | 1,361 | 15:July-19:July |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 240 | 1,258 | 14:July-19:July |
| Emsland Block B | Amprion | Konventionell | positive | 148 | 1,112 | 23:July-07:July |
| GERSTEINW_G (KapRes) | Amprion | Konventionell | positive | 123 | 1,046 | 22:July-07:July |
| UW Büttel | TenneT DE | negative | 108 | 623 | 22:July-04:July | |
| LAUSWARD_GUDF | Amprion | Konventionell | positive | 265 | 596 | 06:July-08:July |
| illwerke vkw AG | TransnetBW | Sonstiges | positive | 57 | 579 | 22:July-22:July |
| BAG NWAK-Cluster 16 Regensburg-Sittling | TenneT DE | negative | 50 | 450 | 08:July-17:July | |
| 50H_EDIS_CR_LV_WU | 50Hertz | negative | 81 | 425 | 07:July-13:July | |
| 50H_EDIS_CR_WU_NORD | 50Hertz | negative | 81 | 425 | 07:July-13:July | |
| Börse | TransnetBW | Sonstiges | negative | 224 | 392 | 22:July-15:July |
| Jänschwalde (Standort) | 50Hertz | Konventionell | negative | 202 | 354 | 06:July-08:July |
| GUD_HERNE_6 | Amprion | Konventionell | positive | 267 | 334 | 07:July-08:July |
| Irsching 4 | TenneT DE | Konventionell | negative | 113 | 310 | 22:July-00:July |
| 50H_EDIS_CR_SOW_Sued | 50Hertz | negative | 92 | 275 | 10:July-13:July | |
| Lippendorf | 50Hertz | Konventionell | negative | 124 | 216 | 06:July-08:July |
| Börse | 50Hertz | Sonstiges | positive | 37 | 167 | 22:July-22:July |
| Braunschweig HKWM GT31 | TenneT DE | Konventionell | positive | 39 | 166 | 04:July-08:July |
| 50H Berlin Marzahn | 50Hertz | Konventionell | negative | 45 | 135 | 04:July-08:July |
| 50H Berlin Lichterfelde | 50Hertz | Konventionell | negative | 60 | 120 | 06:July-08:July |
| 50H_EDIS_CR_PAS | 50Hertz | negative | 69 | 120 | 13:July-15:July | |
| GERSTEINW_F (KapRes) | Amprion | Konventionell | positive | 38 | 85 | 19:July-22:July |
| Jänschwalde (Standort) | 50Hertz | Konventionell | negative | 135 | 68 | 06:July-07:July |
| 50H_EDIS_CR_HND | 50Hertz | negative | 36 | 62 | 09:July-15:July | |
| CHEMIEPARK_MARL_KRAFTWERKE | Amprion | Konventionell | negative | 26 | 58 | 19:July-22:July |
| Boxberg (Standort) | 50Hertz | Konventionell | positive | 10 | 30 | 22:July-01:July |
| INFRA_HOE_GTX2 | Amprion | Konventionell | negative | 12 | 27 | 19:July-22:July |
| 50H Dresden-Reick | 50Hertz | Konventionell | positive | 27 | 27 | 23:July-00:July |
| Börse | TransnetBW | Sonstiges | positive | 35 | 27 | 04:July-06:July |
| 50H PV Witznitz | 50Hertz | negative | 100 | 25 | 08:July-08:July | |
| 50H Erfurt-Ost HKW GuD | 50Hertz | Konventionell | negative | 21 | 21 | 07:July-08:July |
| UW Büttel | TenneT DE | negative | 55 | 14 | 23:July-23:July | |
| Schwarze Pumpe (Standort) | 50Hertz | Konventionell | negative | 50 | 12 | 08:July-08:July |
| 50H PV Bartow | 50Hertz | negative | 50 | 12 | 08:July-08:July | |
| Boxberg (Standort) | 50Hertz | Konventionell | positive | 10 | 10 | 04:July-05:July |
| 50H Halle-Dieselstr HKW-BlockB | 50Hertz | Konventionell | negative | 9 | 9 | 07:July-08:July |
| 50H BASF Schwarzheide | 50Hertz | Konventionell | negative | 7 | 7 | 07:July-08:July |
| 50H Dresden-Reick | 50Hertz | Konventionell | negative | 6 | 6 | 07:July-08:July |
| Börse | TransnetBW | Sonstiges | negative | 1 | 1 | 06:July-08:July |
How BESS Can Reduce These Costs
Battery Energy Storage Systems at congestion points could have avoided an estimated €0.27M of today's redispatch costs by absorbing excess wind energy locally.
Learn BESS Arbitrage (Free) Stromfee AI PlatformFrequently Asked Questions
How much did redispatch cost on 2026-07-21?
On 2026-07-21, estimated redispatch costs were approximately €0.9 million. This includes €0.3M for renewable curtailment compensation and €0.38M for conventional ramp-up costs.
Which power plants were most affected on 2026-07-21?
The most affected plant was Börse (TenneT DE) with 14,873 MWh of positive redispatch.
What was the electricity spot price on 2026-07-21?
The EPEX Day-Ahead spot price for DE_LU ranged from 0 to 177 €/MWh with an average of 113 €/MWh.