2,480MWh Curtailed
2,724MWh Ramped Up
€0.9MEst. Cost
146 MWPeak Positive
Day-Ahead Spot: 90-142 €/MWh (avg 109)
TSO Breakdown
| TSO | Direction | Measures | Total MWh |
|---|---|---|---|
| Amprion | positive | 22 | 57,648 |
| TenneT DE | negative | 12 | 35,801 |
| TenneT DE | positive | 7 | 33,131 |
| 50Hertz | negative | 15 | 22,559 |
| Amprion | negative | 6 | 10,907 |
| TransnetBW | positive | 13 | 8,350 |
| TransnetBW | negative | 1 | 22 |
Plant-Level Redispatch Measures
| Plant | TSO | Fuel | Dir | Avg MW | MWh | Time |
|---|---|---|---|---|---|---|
| Börse | TenneT DE | Sonstiges | positive | 1094 | 26,266 | 23:January-23:February |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 701 | 16,826 | 23:January-23:February |
| Emsland Block D | Amprion | Konventionell | positive | 539 | 12,946 | 23:January-23:February |
| UW Büttel | TenneT DE | negative | 710 | 12,776 | 05:January-23:January | |
| KMW_KW3 | Amprion | Konventionell | positive | 328 | 7,870 | 23:January-23:February |
| WALSUM_10 | Amprion | Konventionell | negative | 327 | 6,546 | 00:January-22:January |
| Jänschwalde (Standort) | 50Hertz | Konventionell | negative | 317 | 5,390 | 06:January-23:January |
| Reservekraftwerk Rheinhafen-Dampfkraftwerk Karlsruhe Block 7 | TransnetBW | Konventionell | positive | 220 | 5,280 | 23:January-23:February |
| Schwarze Pumpe (Standort) | 50Hertz | Konventionell | negative | 319 | 5,109 | 07:January-23:January |
| HAMMUENTROP_10 | Amprion | Konventionell | positive | 288 | 4,754 | 06:January-23:January |
| Knapsack 1 | Amprion | Konventionell | positive | 408 | 4,078 | 06:January-22:January |
| HAMMUENTROP_20 | Amprion | Konventionell | positive | 263 | 3,873 | 07:January-21:January |
| Knapsack 1 | Amprion | Konventionell | positive | 461 | 3,686 | 11:January-19:January |
| HAMMUENTROP_10 | Amprion | Konventionell | positive | 236 | 3,659 | 23:January-23:February |
| Knapsack 1 | Amprion | Konventionell | positive | 306 | 3,364 | 12:January-23:January |
| UW Dörpen-West | TenneT DE | negative | 187 | 3,360 | 05:January-23:January | |
| WEISWEILER_G | Amprion | Konventionell | negative | 181 | 2,720 | 00:January-15:January |
| Emsland Block B | Amprion | Konventionell | positive | 209 | 2,716 | 05:January-18:January |
| Irsching 5 | TenneT DE | Konventionell | positive | 230 | 2,648 | 03:January-14:January |
| Irsching 5 | TenneT DE | Konventionell | positive | 195 | 2,636 | 07:January-23:January |
| Rostock Kohlekraftwerk | 50Hertz | Konventionell | negative | 179 | 2,512 | 07:January-21:January |
| KNAPSACK_20 | Amprion | Konventionell | positive | 229 | 2,409 | 05:January-23:January |
| 50H Berlin Lichterfelde | 50Hertz | Konventionell | negative | 148 | 2,368 | 07:January-23:January |
| Emsland Block C | Amprion | Konventionell | positive | 210 | 2,310 | 23:January-10:February |
| Rostock Kohlekraftwerk | 50Hertz | Konventionell | negative | 128 | 1,538 | 00:January-23:January |
| Boxberg (Standort) | 50Hertz | Konventionell | negative | 254 | 1,526 | 12:January-18:January |
| Emsland Block B | Amprion | Konventionell | positive | 210 | 1,260 | 23:January-05:February |
| Emsland Block B | Amprion | Konventionell | positive | 168 | 1,259 | 15:January-23:January |
| WALSUM_10 | Amprion | Konventionell | negative | 170 | 1,106 | 23:January-17:February |
| ReserveKW Ingolstadt 4 | TenneT DE | Konventionell | positive | 133 | 1,098 | 06:January-20:January |
| UW Büttel | TenneT DE | negative | 315 | 944 | 02:January-05:January | |
| 50H Berlin Lichterfelde | 50Hertz | Konventionell | negative | 61 | 920 | 23:January-14:February |
| 50H Berlin Marzahn | 50Hertz | Konventionell | negative | 60 | 900 | 07:January-22:January |
| 50H Berlin Mitte | 50Hertz | Konventionell | negative | 53 | 897 | 05:January-23:January |
| Heizkraftwerk Heilbronn Block 7 | TransnetBW | Konventionell | positive | 149 | 857 | 07:January-12:January |
| KMW_KW3 | Amprion | Konventionell | positive | 116 | 810 | 16:January-23:January |
| UW Dörpen-West | TenneT DE | negative | 216 | 702 | 23:January-02:February | |
| KNAPSACK_20 | Amprion | Konventionell | positive | 216 | 702 | 23:January-02:February |
| Emsland Block D | Amprion | Konventionell | positive | 120 | 602 | 05:January-12:January |
| 50H Berlin Marzahn | 50Hertz | Konventionell | negative | 46 | 556 | 23:January-14:February |
| illwerke vkw AG | TransnetBW | Sonstiges | positive | 165 | 496 | 02:January-05:January |
| KNAPSACK_20 | Amprion | Konventionell | positive | 167 | 460 | 10:January-12:January |
| UW Dörpen-West | TenneT DE | negative | 190 | 380 | 06:January-08:January | |
| Rostock Kohlekraftwerk | 50Hertz | Konventionell | negative | 125 | 376 | 23:January-02:February |
| OWP Nordergründe | TenneT DE | negative | 84 | 337 | 01:January-05:January | |
| illwerke vkw AG | TransnetBW | Sonstiges | positive | 96 | 335 | 12:January-22:January |
| HAMMUENTROP_10 | Amprion | Konventionell | positive | 101 | 304 | 20:January-23:January |
| WEISWEILER_G | Amprion | Konventionell | negative | 100 | 300 | 23:January-02:February |
| NIEHL-31-GUD | Amprion | Konventionell | positive | 46 | 278 | 08:January-23:January |
| Heizkraftwerk Altbach/Deizisau Block 2 | TransnetBW | Konventionell | positive | 93 | 278 | 02:January-05:January |
How BESS Can Reduce These Costs
Battery Energy Storage Systems at congestion points could have avoided an estimated €0.27M of today's redispatch costs by absorbing excess wind energy locally.
Learn BESS Arbitrage (Free) Stromfee AI PlatformFrequently Asked Questions
How much did redispatch cost on 2026-01-31?
On 2026-01-31, estimated redispatch costs were approximately €0.9 million. This includes €0.25M for renewable curtailment compensation and €0.38M for conventional ramp-up costs.
Which power plants were most affected on 2026-01-31?
The most affected plant was Börse (TenneT DE) with 26,266 MWh of positive redispatch.
What was the electricity spot price on 2026-01-31?
The EPEX Day-Ahead spot price for DE_LU ranged from 90 to 142 €/MWh with an average of 109 €/MWh.