3,243MWh Curtailed
4,425MWh Ramped Up
€1.33MEst. Cost
310 MWPeak Positive
Day-Ahead Spot: 110-248 €/MWh (avg 157)
TSO Breakdown
| TSO | Direction | Measures | Total MWh |
|---|---|---|---|
| TenneT DE | negative | 37 | 104,546 |
| Amprion | positive | 29 | 58,458 |
| TenneT DE | positive | 9 | 27,462 |
| 50Hertz | negative | 32 | 21,104 |
| TransnetBW | positive | 2 | 6,812 |
| 50Hertz | positive | 3 | 1,268 |
| Amprion | negative | 2 | 1,227 |
Plant-Level Redispatch Measures
| Plant | TSO | Fuel | Dir | Avg MW | MWh | Time |
|---|---|---|---|---|---|---|
| UW Dörpen-West | TenneT DE | negative | 1676 | 30,169 | 04:October-22:October | |
| Börse | TenneT DE | Sonstiges | positive | 942 | 16,019 | 22:October-22:October |
| UW Diele | TenneT DE | negative | 853 | 16,001 | 03:October-22:October | |
| UW Dörpen-West | TenneT DE | negative | 1751 | 10,506 | 22:October-04:October | |
| GUD_HERNE_6 | Amprion | Konventionell | positive | 569 | 7,969 | 08:October-22:October |
| UW Emden-Ost | TenneT DE | negative | 603 | 7,839 | 04:October-22:October | |
| LAUSWARD_GUDF | Amprion | Konventionell | positive | 385 | 6,645 | 22:October-15:October |
| Wilhelmshaven | TenneT DE | Konventionell | negative | 587 | 6,599 | 22:October-09:October |
| Rheinhafen-Dampfkraftwerk Karlsruhe Block 8 | TransnetBW | Konventionell | positive | 576 | 6,332 | 22:October-09:October |
| UW Diele | TenneT DE | negative | 1031 | 6,184 | 22:October-04:October | |
| Emsland Block D | Amprion | Konventionell | positive | 734 | 5,876 | 22:October-06:October |
| UW Emden-Ost | TenneT DE | negative | 941 | 5,644 | 22:October-04:October | |
| LAUSWARD_GUDF | Amprion | Konventionell | positive | 335 | 5,441 | 00:October-22:October |
| UW Büttel | TenneT DE | negative | 462 | 4,616 | 04:October-22:October | |
| WEISWEILER_H | Amprion | Konventionell | positive | 365 | 4,467 | 22:October-11:October |
| GUD_HERNE_6 | Amprion | Konventionell | positive | 530 | 3,710 | 22:October-05:October |
| Rostock Kohlekraftwerk | 50Hertz | Konventionell | negative | 220 | 3,525 | 06:October-22:October |
| Emsland Block B | Amprion | Konventionell | positive | 241 | 3,371 | 02:October-16:October |
| Irsching 4 | TenneT DE | Konventionell | positive | 385 | 2,884 | 14:October-22:October |
| Irsching 4 | TenneT DE | Konventionell | positive | 309 | 2,859 | 22:October-07:October |
| HAMMUENTROP_20 | Amprion | Konventionell | positive | 271 | 2,715 | 22:October-08:October |
| WEISWEILER_G | Amprion | Konventionell | positive | 260 | 2,602 | 22:October-12:October |
| Irsching 5 | TenneT DE | Konventionell | positive | 235 | 2,588 | 03:October-22:October |
| Emsland Block C | Amprion | Konventionell | positive | 296 | 2,370 | 22:October-22:October |
| Lippendorf | 50Hertz | Konventionell | negative | 372 | 2,231 | 22:October-11:October |
| KNAPSACK_20 | Amprion | Konventionell | positive | 293 | 2,124 | 22:October-05:October |
| BAG NWAK-Cluster 17 Altheim | TenneT DE | negative | 300 | 2,100 | 08:October-15:October | |
| Boxberg (Standort) | 50Hertz | Konventionell | negative | 322 | 1,933 | 23:October-12:October |
| BAG NWAK-Cluster 16a Regensburg-Sittling | TenneT DE | negative | 226 | 1,862 | 08:October-16:October | |
| Schwarze Pumpe (Standort) | 50Hertz | Konventionell | negative | 262 | 1,572 | 08:October-22:October |
| Irsching 5 | TenneT DE | Konventionell | positive | 217 | 1,411 | 23:October-06:October |
| UW Büttel | TenneT DE | negative | 400 | 1,400 | 18:October-22:October | |
| WEISWEILER_G | Amprion | Konventionell | positive | 173 | 1,381 | 08:October-16:October |
| AVA Cluster Voslapp | TenneT DE | negative | 248 | 1,300 | 16:October-22:October | |
| Irsching 5 | TenneT DE | Konventionell | positive | 355 | 1,244 | 22:October-01:October |
| Boxberg (Standort) | 50Hertz | Konventionell | negative | 153 | 1,224 | 08:October-22:October |
| LAUSWARD_GUDF | Amprion | Konventionell | positive | 135 | 1,215 | 02:October-22:October |
| NIEHL-31-GUD | Amprion | Konventionell | positive | 170 | 1,189 | 02:October-22:October |
| UW Büttel | TenneT DE | negative | 196 | 1,176 | 22:October-04:October | |
| GUD_HERNE_6 | Amprion | Konventionell | positive | 290 | 1,158 | 00:October-04:October |
| UW Diele | TenneT DE | negative | 278 | 1,110 | 00:October-04:October | |
| AVA Cluster Voslapp | TenneT DE | negative | 150 | 1,088 | 22:October-05:October | |
| Schkopau | 50Hertz | Konventionell | positive | 216 | 1,079 | 09:October-14:October |
| 50H Berlin Marzahn | 50Hertz | Konventionell | negative | 78 | 1,014 | 22:October-15:October |
| Lippendorf | 50Hertz | Konventionell | negative | 118 | 1,006 | 08:October-22:October |
| UW Büttel | TenneT DE | negative | 400 | 1,000 | 11:October-14:October | |
| LAUSWARD_GUDF | Amprion | Konventionell | positive | 82 | 982 | 08:October-22:October |
| HAMMUENTROP_20 | Amprion | Konventionell | positive | 131 | 916 | 07:October-20:October |
| 50H Berlin Mitte | 50Hertz | Konventionell | negative | 70 | 906 | 22:October-15:October |
| Kiel (Küstenkraftwerk gesamt) | TenneT DE | Konventionell | negative | 113 | 904 | 03:October-18:October |
How BESS Can Reduce These Costs
Battery Energy Storage Systems at congestion points could have avoided an estimated €0.4M of today's redispatch costs by absorbing excess wind energy locally.
Learn BESS Arbitrage (Free) Stromfee AI PlatformFrequently Asked Questions
How much did redispatch cost on 2026-10-13?
On 2026-10-13, estimated redispatch costs were approximately €1.33 million. This includes €0.32M for renewable curtailment compensation and €0.83M for conventional ramp-up costs.
Which power plants were most affected on 2026-10-13?
The most affected plant was UW Dörpen-West (TenneT DE) with 30,169 MWh of negative redispatch.
What was the electricity spot price on 2026-10-13?
The EPEX Day-Ahead spot price for DE_LU ranged from 110 to 248 €/MWh with an average of 157 €/MWh.