2,701MWh Curtailed
2,277MWh Ramped Up
€0.7MEst. Cost
150 MWPeak Positive
Day-Ahead Spot: 30-161 €/MWh (avg 109)
TSO Breakdown
| TSO | Direction | Measures | Total MWh |
|---|---|---|---|
| TenneT DE | positive | 22 | 33,076 |
| TenneT DE | negative | 20 | 20,492 |
| Amprion | positive | 10 | 12,146 |
| 50Hertz | negative | 22 | 3,358 |
| TransnetBW | positive | 10 | 1,732 |
| Amprion | negative | 4 | 596 |
| 50Hertz | positive | 14 | 374 |
| TransnetBW | negative | 2 | 358 |
Plant-Level Redispatch Measures
| Plant | TSO | Fuel | Dir | Avg MW | MWh | Time |
|---|---|---|---|---|---|---|
| ReserveKW Zolling 5 | TenneT DE | Konventionell | positive | 288 | 6,915 | 22:May-22:May |
| ReserveKW Zolling 5 | TenneT DE | Konventionell | positive | 288 | 6,915 | 22:May-22:May |
| Knapsack 1 | Amprion | Konventionell | positive | 467 | 5,721 | 22:May-22:May |
| Knapsack 1 | Amprion | Konventionell | positive | 467 | 5,721 | 22:May-22:May |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 479 | 4,312 | 22:May-07:May |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 479 | 4,312 | 22:May-07:May |
| Börse | TenneT DE | Sonstiges | positive | 492 | 3,688 | 07:May-19:May |
| Börse | TenneT DE | Sonstiges | positive | 492 | 3,688 | 07:May-19:May |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 267 | 2,338 | 12:May-21:May |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 267 | 2,338 | 12:May-21:May |
| UW Büttel | TenneT DE | negative | 217 | 1,950 | 04:May-17:May | |
| UW Büttel | TenneT DE | negative | 217 | 1,950 | 04:May-17:May | |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 203 | 1,220 | 16:May-22:May |
| Wilhelmshaven (ENGIE) | TenneT DE | Konventionell | negative | 203 | 1,220 | 16:May-22:May |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 221 | 1,218 | 22:May-03:May |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 221 | 1,218 | 22:May-03:May |
| 50H_EDIS_CR_WU | 50Hertz | negative | 166 | 912 | 07:May-12:May | |
| 50H_EDIS_CR_WU | 50Hertz | negative | 166 | 912 | 07:May-12:May | |
| UW Büttel | TenneT DE | negative | 300 | 900 | 11:May-14:May | |
| UW Büttel | TenneT DE | negative | 300 | 900 | 11:May-14:May | |
| Hannover-Linden GuD | TenneT DE | Konventionell | positive | 151 | 868 | 14:May-20:May |
| Hannover-Linden GuD | TenneT DE | Konventionell | positive | 151 | 868 | 14:May-20:May |
| Hannover-Linden GuD | TenneT DE | Konventionell | positive | 143 | 858 | 01:May-07:May |
| Hannover-Linden GuD | TenneT DE | Konventionell | positive | 143 | 858 | 01:May-07:May |
| UW Büttel | TenneT DE | negative | 180 | 719 | 00:May-04:May | |
| UW Büttel | TenneT DE | negative | 180 | 719 | 00:May-04:May | |
| illwerke vkw AG | TransnetBW | Sonstiges | positive | 130 | 519 | 16:May-22:May |
| illwerke vkw AG | TransnetBW | Sonstiges | positive | 130 | 519 | 16:May-22:May |
| Irsching 4 | TenneT DE | Konventionell | negative | 150 | 450 | 19:May-22:May |
| Irsching 4 | TenneT DE | Konventionell | negative | 150 | 450 | 19:May-22:May |
| Kiel (Küstenkraftwerk gesamt) | TenneT DE | Konventionell | negative | 69 | 344 | 01:May-06:May |
| Kiel (Küstenkraftwerk gesamt) | TenneT DE | Konventionell | negative | 69 | 344 | 01:May-06:May |
| AVA Cluster Voslapp | TenneT DE | negative | 120 | 300 | 12:May-14:May | |
| AVA Cluster Voslapp | TenneT DE | negative | 120 | 300 | 12:May-14:May | |
| Schwarze Pumpe (Standort) | 50Hertz | Konventionell | negative | 147 | 294 | 14:May-16:May |
| Schwarze Pumpe (Standort) | 50Hertz | Konventionell | negative | 147 | 294 | 14:May-16:May |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 185 | 278 | 20:May-22:May |
| ReserveKW Staudinger 5 | TenneT DE | Konventionell | positive | 185 | 278 | 20:May-22:May |
| Heizkraftwerk Stuttgart-Münster GT 88 | TransnetBW | Konventionell | positive | 54 | 270 | 15:May-20:May |
| Heizkraftwerk Stuttgart-Münster GT 88 | TransnetBW | Konventionell | positive | 54 | 270 | 15:May-20:May |
| Hannover-Linden GuD | TenneT DE | Konventionell | positive | 34 | 250 | 22:May-20:May |
| Hannover-Linden GuD | TenneT DE | Konventionell | positive | 34 | 250 | 22:May-20:May |
| Netzreservekraftwerk GTKW-DA-POOL | Amprion | Konventionell | positive | 73 | 220 | 16:May-19:May |
| Netzreservekraftwerk GTKW-DA-POOL | Amprion | Konventionell | positive | 73 | 220 | 16:May-19:May |
| WALSUM_10 | Amprion | Konventionell | negative | 166 | 208 | 15:May-16:May |
| WALSUM_10 | Amprion | Konventionell | negative | 166 | 208 | 15:May-16:May |
| 50H Hamburg Wedel1 | 50Hertz | Konventionell | negative | 36 | 180 | 02:May-07:May |
| 50H Hamburg Wedel1 | 50Hertz | Konventionell | negative | 36 | 180 | 02:May-07:May |
| Börse | TransnetBW | Sonstiges | negative | 143 | 179 | 19:May-21:May |
| Börse | TransnetBW | Sonstiges | negative | 143 | 179 | 19:May-21:May |
How BESS Can Reduce These Costs
Battery Energy Storage Systems at congestion points could have avoided an estimated €0.21M of today's redispatch costs by absorbing excess wind energy locally.
Learn BESS Arbitrage (Free) Stromfee AI PlatformFrequently Asked Questions
How much did redispatch cost on 2026-05-15?
On 2026-05-15, estimated redispatch costs were approximately €0.7 million. This includes €0.27M for renewable curtailment compensation and €0.32M for conventional ramp-up costs.
Which power plants were most affected on 2026-05-15?
The most affected plant was ReserveKW Zolling 5 (TenneT DE) with 6,915 MWh of positive redispatch.
What was the electricity spot price on 2026-05-15?
The EPEX Day-Ahead spot price for DE_LU ranged from 30 to 161 €/MWh with an average of 109 €/MWh.